TM  10-3930-643-34 HYDRAULIC  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 12-5. Fork Valve Assembly. (Sheet 6 of CLEANING/INSPECTION l TOXIC/FLAMMABLE 30. 31. 32. Dry  cleaning  solvent  P-D-680,  used for cleaning parts, is toxic and flammable. Use  only  in  well ventilated areas. Wear protective goggles and gloves. Do not smoke or allow open flames or sparks in areas where cleaning solvent is used or stored. Avoid contact with eyes, skin or clothing. If contact with eyes is made, flush with cold water and seek medical attention  immediately. If contact with skin or clothing is made, flush with cold water. If you become  dizzy  while  using  cleaning solvent, get fresh air immediately. l COMPRESSED  AIR  HAZARD Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment  (goggles/shield,  gloves, etc.). 9) Wipe all parts moistened with P-D-680. Dry compressed air. with clean cloth cleaning solvent thoroughly with Refer to paragraph 2-8. All grooves and passages in housing (37) must be free of foreign matter. Inspect housing (37) surfaces for burrs,    scratches, nicks or scores. Stone or lap all burrs. Use crocus cloth on small scores. Inspect all other parts. Refer to paragraph 2-9. Go to sheet 7 12-38