TM  10-3930-643-34 HYDRAULIC  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 12-3. Loader Control Valve. (Sheet 5 of 14) CLEANING/INSPECTION 16. Wipe hose assemblies (18 thru 20) with  clean  cloth  moistened  with detergent. Wipe dry with clean cloth. l TOXIC/FLAMMABLE Dry  cleaning  solvent  P-D-680,  used for cleaning parts, is toxic and flammable. Use  only  in  well ventilated  areas. Wear  protecive goggles and gloves. Do not smoke or allow open flames or sparks in areas where cleaning solvent is used or stored. Avoid contact with eyes, skin or clothing. If contact with eyes is made, flush with cold water and seek medical attention  immediately. If contact with skin or clothing is made, flush with cold water. If you become  dizzy  while  using  cleaning solvent, get fresh air immediately. l COMPRESSED  AIR  HAZARD Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment  (goggles/shield,  gloves, etc.). 17. Clean all other parts except valve assemblies  (44  thru  47)  with  cleaning solvent  P-D-680. Dry  thoroughly  with compressed air. Refer to paragraph 2-8. 18. Inspect all parts except valve assemblies (44 thru 47). Refer to paragraph  2-9. Go to sheet 6 12-17