TM  10-3930-643-34 GENERAL  MAINTENANCE  PROCEDURES.  (cont) 2-13. Electrical  Repairs.  (cont) (4) Flag-type connector, terminal with shell. DISASSEMBLY Cut wire close to terminal. Remove and discard terminal. ASSEMBLY 1. Strip wire, refer to Wire Size Chart. Do not nick or cut strands. 2. Tin bare wires. Use resin-core solder to coat bare wires. If using solid core solder, clean wires with flux before tinning. 3. Roll back insulation on new terminal to expose crimping area. 4. Insert new wire in terminal. 5. Crimp new terminal. Securely fasten wires to new terminal. 6. Unroll insulation on new terminal to cover parts. 2-20