TM  10-3930-643-34 GENERAL  MAINTENANCE  PROCEDURES. 2-13. Electrical  Repairs. (3) Terminal-type connector, pin and socket. DISASSEMBLY 1. Slide shell (3) back on the wire (4) to expose metal parts. 2. Remove C-washer (1). 3. Cut wire (4) close to terminal (2). Remove and discard terminal (2). 4. Remove shell (3). ASSEMBLY 1. Strip wire (4), refer to Wire Size Chart. Do not nick or cut strands. 2. Tin bare wires. Use resin-core solder to coat bare wires. If using solid core solder,   clean wires with flux before tinning. 3. Slide shell (3) onto wire (4). NOTE New terminal must be selected to match the size of the mating contact at the terminal connection. New terminal must also match the crimping area with the thickness of the wire. 4. Insert wire (4) into new terminal (2). 5. Crimp terminal (2). Securely fasten wire (4) to terminal (2). 6. Install C-washer (1). NOTE Shell is held in position over terminal by the C-washer. Make sure the C-washer is firmly seated in shell. 7. Slide shell (3) up over new terminal (2) and C-washer (1). 2-19