TM  10-3930-643-34 TRANSMISSION  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 6-3. Torque Converter. (Sheet 6 of 9) CLEANING/INSPECTION 28. Wipe hose assemblies (1, 2, 3, 8, 12, 29. 30. 31. 16 and 20) with clean cloth moistened with  detergent  and  water  solution. TOXIC/FLAMMABLE Dry  cleaning  solvent  P-D-680,  used for cleaning parts, is toxic and flammable. Use  only  in  well ventilated  areas. Wear  protective goggles and gloves. Do not smoke or allow open flames or sparks in areas where cleaning solvent is used or stored. Avoid contact with eyes, skin or clothing. If contact with eyes is made, flush with cold water and seek medical attention  immediately. If contact with skin or clothing is made, flush with cold water. If you become  dizzy  while  using  cleaning solvent, get fresh air immediately. COMPRESSED AIR HAZARD Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment  (goggles/shield,  gloves, etc.). Wipe outer surface  of torque converter (28) with clean cloth dampened with cleaning solvent P-D-680. Allow to air dry. Clean all other parts with cleaning solvent P-D-680. Dry  thoroughly  with compressed air. Refer to paragraph 2-8. Inspect all parts. Refer to para- graph 2-9. Go to sheet 7 6-16