TM  10-3930-643-34 ELECTRICAL  SYSTEM  MAINTENANCE.  (cont) 5-3. Main Wiring Harness. (Sheet 15 of 15) INSTALLATION  (cont) 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. NOTE The following is a difference between  M10A  Forklift  models. Connect two wire assemblies (10) at terminals  to backup alarm, from vehicles S/N 2001 and above. Apply silicone sealant over entire connection. Connect three wire assemblies (9) at terminals to left stop light and taillight. Apply silicone sealant over entire connection. Connect two wire assemblies (8 and 7) at connectors to blackout lights. Apply silicone sealant over entire connection. Connect three wire assemblies (6) at terminals to right stop light and taillight. Apply silicone sealant over entire connection. Using a 9/16” socket and socket wrench  handle,  install  four clamps (5), washers (4), nuts (3) and bolts (2). Install a suitable number of tie straps (1) to secure harness to vehicle. NOTE Return M10A Forklift to original equipment  condition. END OF TASK 5-40