TM  10-3930-643-34 ELECTRICAL  SYSTEM  MAINTENANCE. 5-3. Main Wiring Harness. (Sheet 12 of 15) INSTALLATION 58. Connect  wire assembly (41) at connector to ether start valve. 59. Apply silicone sealant over entire connection. NOTE The following is a difference between  M10A  Forklift  models. 60. Using a 9/16” open end wrench, install clamp (40), washer (39) and bolt (38), from vehicles S/N 2000 and below. 61. Install clamp (37), washer (36) and bolt (35). 62. Install clamp (34), washer (33) and bolt (32) in front, left side of engine. 63. Using a 3/8”   open end wrench, connect two wire assemblies (31) at terminals to torque converter temperature sender. 64. Apply  silicone connection. sealant over entire Go to sheet 13 5-37