TM  10-3930-643-34 ELECTRICAL  SYSTEM  MAINTENANCE.  (cont) 5-1. Starting Motor. (Sheet 15 of 15) ADJUSTMENT Only personnel with training and experience  in  handling  potentially hazardous electrical testing procedures may perform the next procedure. An insulating glove and/or insulated tool should be used. 93. 94. 95. 96. 97. 98. 99. Momentarily  touch  jumper  lead  A  from battery negative to MTR terminal. Drive will shift  into cranking position. Push on drive to take up movement. Measure pinion clearance. It should be 0.36 inches. Adjust  pinion  clearance,  if  required, by turning locknut. Remove three jumper leads. Connect lead assembly (12) to starting motor solenoid. Install new gasket (2) and plug (1). NOTE Return M10A Forklift to original equipment  condition. END OF TASK 5-16