TM   10-3930-643-20 APPENDIX E. (cont) b . Table   E-2. Torque   Limits   for   Hose   Clamps. This t a b l e    p r o v i d es tightening   torques   for   hose   clamps   used   in   all   rubber   applications (radiator, air   cleaner,   operating   level   boots,   hydraulic   system,   etc.). TORQUE  PLUS  OR  MINUS  0.6  N.m  (5  in-lb) RADIATOR,   AIR HYDRAULIC CLEANER,  BOOTS,  ETC. SYSTEM CLAMP INCH NEWTON INCH NEWTON TYPE & SIZE POUNDS METER POUNDS METERS “T”   Bolt   (Any   Diameter) 55-60 6-7 40-50 5-6 Worm   Drive--25-50   mm(1-2 in.)   Open   Diameter   & Under 25 3 25 3 Worm   Drive--50-102   mm (2-4   in.)   Open   Diameter 100 11 - - - - - - - - c . Table   E-3. Torque   Limits   for   Split   Flange   Connections. T h i s    t a b l e provides   tightening   torques   for   split   flange   connections   used   in   hydraulic systems. Split   flanges   and   fitting   shoulders   should   fit   squarely. I n s t a l l    a ll bolts   finger   tight   and   then   torque   evenly. Do   not   overtorque   bolts   or   damage to   flanges   and/or   bolts   may   occur   and   leakage   may   result. FLANGE SIZE  (*) 13 19 25 32 38 51 64 76 89 1/2 3/4 1 1 - 1 /4 1-1/2 2 2 - 1 /2 3 3 - 1 /2 BOLT SIZE 5/16 3 /8 3 /8 7/16 1/2 1/2 1/2 5/8 5 /8 BOLT TORQUE IN  FOOT POUNDS MIN. 15 22 27 35 46 55 79 138 117 MAX. 18 27 35 45 58 65 91 150 133 BOLT   TORQUE IN  NEWTON METERS MIN. 20 30 37 48 62 75 107 187 159 MAX. 24 37 48 61 79 88 123 203 180 MAX. WORKING PRESSURE kPa 34474 34474 34474 27579 20684 20684 17237 13790 3447 p si 5000 5000 5000 4000 3000 3000 2500 2000 500 (*)   Inside   diameter   of   hydraulic   tube   or   hose   fitting. E -2

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business