TM   10-3930-643-20 NON-ELECTRICAL  GAGES  MAINTENANCE.  (cont) 15-2. Air  Pressure  Gage.  (sheet  2  of  3) REMOVAL (cont) 3. Using   a   flat   blade   screwdriver, remove   screw   (4)   and   lock   washer ( 5 ) . NOTE All   wire   must   be   tagged   when removed   from   connector.   Indicate whether   wire   is   connected   to   pin- type   or   socket-type   connector. 4. Disconnect   wire   assembly   (6). NOTE Tag   all   hose   and   tube   assemblies before   disconnecting   to   aid   in i n s t a l l a t i o n. 5. Using   a   7/16”   open   end   wrench, disconnect   hose   assembly   (7). 6. Remove  elbow  (8). 7. Remove   connector   (9). 8 . Using   3/4”   and   9/16”   open   end wrenches,   remove   reducer   (10)   and t e e    ( 1 1 ). 9. Disconnect   wire   assembly   (12). 10. Remove   lamp   (13). 11. U s i n g    a    3 / 8 ”    s o c k e t    a n d    s o c k et wrench  handle,  remove  two  nuts  (14) and   lock   washers   (15). 12. Remove   bracket   (16). 13. Remove   gage   (17). Go  to  sheet  3 15-6