TM   10-3930-643-20 NON-ELECTRICAL  GAGES  MAINTENANCE. 15-1. Air  Cleaner  Filter  Indicator  (Sheet  2  of  3) CLEANING/INSPECTION 6. C l e a n    a i r    f i l t e r    c l e a n e r    i n d i c a t or (1)   with   mild   detergent   and   water s o l u t i o n. Dry   cleaning   solvent   P-D-680   used for   cleaning   parts,   is   toxic   and f l a m m a b l e .    U s e    o n l y    i n    w e l l ventilated   areas.   Wear   protective goggles   and   gloves.   Do   not   smoke or   allow   open   flames   or   sparks   in areas   where   cleaning   solvent   is u s e d    o r    s t o r e d .    A v o i d    c o n t a ct w i t h    e y e s ,    s k i n    o r    c l o t h i n g .    If contact   with   eyes   is   made,   flush with   cold   water   and   seek   medical attention   immediately.   If   contact with   skin   or   clothing   is made, f l u s h    w i t h    c o l d    w a t e r .    I f    y ou become   dizzy   while   using   cleaning s o l v e n t ,    g e t fresh a ir immediately. COMPRESSED AIR HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h ip guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ). 7. Clean   holes   in   orificed   adapter   (2) with   .020”   mechanic’s   wire. 8. Clean   all   other   parts   with   cleaning solvent   P-D-680. Dry   thoroughly with   compressed   air. R e f e r    t o paragraph   2-8. 9. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. Go  to   sheet   3 15-3