TM   10-3930-643-20 BRAKE  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 8-15. Air   Tanks   Hoses,   Lines   and   Fittings.   (Sheet   8   of   13) CLEANING/INSPECTION 53. 54. Clean   tubes   (7,   14,   22,   29,   38,   46 and   54)   with   mild   detergent and water   solution.   Wipe   dry. WARNING l TOXIC/FLAMMABLE Dry   cleaning solvent    P-D-680, used   for   cleaning   parts,   is   toxic and   flammable.   Use   only   in   well v e n t i l a t e d     a r e a s. Wear protective   goggles   and   gloves. Do  not  smoke  or  allow   open   flames or   sparks   in   areas   where   cleaning solvent   is   used   or   stored. Avoid contact   with   eyes, s k i n    or c l o t h i n g. If   contact   with   eyes is   made,   flush   with   cold   water and seek medical attention immediately. I f    c o n t a c t    w i th skin   or   clothing   is   made, f l u sh with   cold   water. If   you become d i z z y    w h i l e    u s i n g    c l e a n i n g s o l v e n t ,    g e t fresh a ir immediately. l COMPRESSED AIR HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h ip guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ). Clean   all   other   parts   with   cleaning solvent   P-D-680. Dry   thoroughly with   compressed   air. R e f e r    t o paragraph   2-8. Go  to  sheet  9 8-92