TM   10-3930-643-20 BRAKE  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 8-14. Power   Cluster/Pressure   Converter   Hoses,   Lines   and   Fittings.   (Sheet   7   of 11) CLEANING/INSPECTION 46. Clean   tubes   (7,14,21,26,35   and   43) with   warm   water   and   detergent. W  A  R  N  I  N  G l   TOXIC/FLAMMABLE Dry   cleaning   solvent   P-D-680   used for   cleaning   parts,   is   toxic   and f l a m m a b l e .    U s e    o n l y    i n    w e ll ventilated   areas.   Wear   protective goggles  and  gloves.  Do  not  smoke or   allow   open   flames   or   sparks   in areas   where   cleaning   solvent   is u s e d    o r    s t o r e d .    A v o i d    c o n t a ct w i t h    e y e s ,    s k i n    o r    c l o t h i n g .    If contact   with   eyes   is   made,   flush with   cold   water   and   seek   medical attention   immediately.   If   contact with   skin   or   clothing   is made, flush   with   cold   water. I f    y o u become   dizzy   while   using   cleaning s o l v e n t ,    g e t f r e sh a ir immediately. l  COMPRESSED  AIR  HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h i p guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ). 47. Clean   all   other   parts   with   cleaning solvent   P-D-680. Dry   thoroughly with   compressed   air. R e f e r    t o paragraph   2-8. Go  to  sheet  8 8-80