TM   10-3930-643-20 TRANSMISSION TROUBLESHOOTING AND MAINTENANCE. (cont) 6-3.   Torque   Converter   High   Pressure   Regulator   Valves.   (Sheet  5  of  8) DISASSEMBLY  (cont) 15. Using   a   1-1/4"   open   end   wrench, r e m o v e    p l u g    ( 2 8 ) ,    g a s k e t    ( 2 9 ), spring   (30),   spring   (31)   and   piston (32)   from   valve   body   (27).   Discard g a s k e t    ( 2 9 ) .    R e m o v e    a l l    g a s k et material   from   mounting   surfaces. CLEANING/INSPECTION WARNING TOXIC/FLAMMABLE Dry   cleaning   solvent   P-D-680   used for   cleaning   parts,   is   toxic   and f l a m m a b l e .    U s e    o n l y    i n    w e ll ventilated   areas.   Wear   protective goggles   and   gloves.   Do   not   smoke or   allow   open   flames   or   sparks   in areas   where   cleaning   solvent   is u s e d    o r    s t o r e d .    A v o i d    c o n t a ct w i t h    e y e s ,    s k i n    o r    c l o t h i n g .    I f contact   with   eyes   is   made,   flush with   cold   water   and   seek   medical attention   immediately.   If   contact with   skin   or   clothing   is made, flush   with   cold   water. I f    y o u become   dizzy   while   using   cleaning s o l v e n t ,    g et fresh a i r immediately. 16. C l e a n    a l l    p a r t s    w i t h    c l e a n i ng solvent   P-D-680. with   clean   cloth. graph   2-8. 17. Inspect   all   parts. graph   2-9. Dry   thoroughly R e f e r    t o    p a r a- R e f e r    t o    p a r a- Go  to  sheet  6 6-18