TM   10-3930-643-20 GENERAL MAINTENANCE PROCEDURES. 2-13. Electrical   Repair. NOTE The   following   examples   show   how   to   read both    multimeters. 1   AN/URM-105. Read   the   DC   volts   scale For   the   range   at   which   the   selector switch   is   set. SWITCH SETTING SCALE 1000  DC  Volts 0-10   (and   multiply   by 100  DC  Volts 0-10   (and   multiply   by 10  DC  Volts 0-10   (read   the   number 1  DC  Volts  0-10 (and   divide   by   10) 100) 10) on   scale) Thus   the   meter   illustrated   is   showing   the   following   readings: SWITCH SETTING READING 1000  DC  Volts 200   Volts   DC 100  DC  Volts 20   Volts   DC 10  DC  Volts 2  Volts  DC 1  DC  Volts 0.2   Volts   DC 2   TS-352   B/U. Read   the   DC   volts   scale   for   the   range   at   which   the   red lead   is   plugged. RANGE SCALE 50V 10V 2.5V Thus   the RANGE 50V 10V 2.5V meter   illustrated 0-5   (and   multiply   by   10) 0-10   (read   the   number   on   the   scale) 0-2.5   (read   the   number   on   the   scale) is   showing   the   following   readings: READING 20   volts   DC 4  volts  DC 1  volt  DC 2-13