TM   10-3930-643-20 GENERAL  MAINTENANCE  PROCEDURES. 2-13. Electrical    Repair. (d)   Connect   the   probes circuit   or   item   to   be   q   easured. across the The   example shows   measuring   the   resistance   of   one   wire   in   a three-wire   cable. (e)   Read   the   meter.   If   the   meter   switch is   on   the   RX1   or   X1   range,   the   reading   is   taken directly   from   the   top   scale.   If   the   meter   switch is   on   a   different   range,   multiply   the   reading   on the   scale   according   to   the   table   below. OHMS  SWITCH  SETTING SCALE X1  or  RX1 Read  number  on  scale X10  or  RX10 Multiply   reading   by   10 X100  or  RX100 Multiply   reading   by   100 X1K or RX1K Multiply   reading   by   1000 X10K  or  RX10K Multiply   reading   by   10,000 For   example,   the   meters   show   the   following   readings: OHMS  SWITCH  SETTING READING X1  or  RX1 40  ohms X10  or  RX10 400  ohms ( 4 )    U s i ng   the   DC   volts   scale. Setting   up   the   meter.   Before   using   the multimeter   to   measure   DC   voltage,   do   the   following   steps   pertaining   to the multimeter   you   have. CAUTION Multimeter   must   be   set   to   a   voltage   range measured   or   multimeter   could   be   damaged. NOTE higher t h a n    t h a t    b e i ng Before   using   multimeter,   check   the   mechanical   zero   of   the   meter.   If the   meter   pointer   is   not   exactly   over   the   zero   line,   reset   by   using the   proper   size   screwdriver   to   adjust   the   small   screw. 2-11