TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-46. Back-Up   Alarm   (S/N   2001   and   above).   (Sheet   2   of   3) REMOVAL NOTE All   electrical   connections,   execpt those   on   the   instrument   panel,   are s e a l e d    a g a i n st moisture with s i l i c o n e    s e a l a n t. Remove   all silicone   sealant   before   performing maintenance on e l e c t r i c al connections. All   wire   must   be   tagged   when   removed from   connector. Indicate   whether w i r e    i s    c o n n e c t e d    t o    p i n - t y p e    or socket-type   connector. 1. Using   an   11/32”   open   end   wrench, remove   nut   (1). 2. D i s c o n n e c t    w i r e    a s s e m b l y    ( 2 )    a t terminal. 3. Remove   nut   (3). 4. Disconnect   wire   assembly   (4)   at terminal. 5. Using   a   9/16”   open   end   wrench, remove   two   nuts   (5),   washers   (6)   and b o l t s    ( 7 ) . 6. Remove   alarm   (8). CLEANING/INSPECTION 7. Clean   all   parts   with   mild   detergent a n d    w a t e r    s o l u t i o n .    W i p e    d r y . Refer   to   paragraph   2-8. 8. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph  2-9. Go  to  sheet  3 5-221