TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-44. Low   Air   Pressure   Switch.   (Sheet   2   of   2) REMOVAL  (cont) 4. Disconnect   wire   assembly   (5). 5. Using   a   3/4”   open   end   wrench,   remove reducer   (6)   and   low a i r    p r e s s u r e switch   (7). CLEANING/INSPECTION 6. Clean   all   parts   with   mild   detergent and   water   solution.   Wipe   dry   with clean    cloth. R e f e r    t o    p a r a g r a ph 2-8. 7. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. INSTALLATION. 8. 9. 10. 11. 12. Using   a   3/4”   open   end   wrench, install   low   air   pressure   switch   (7) and   reducer   (6). Connect   wire   assembly   (5). U s i n g    a    f l a t    t i p    s c r e w d r i v e r , install   screw   (4)   and   secure wire assembly   (5)   on   low a i r     p r e s s u re switch   (7). Position   instrument   panel (3) in h o u s i n g    i n    f r o n t    o f    o p e r a t o r ’ s compartment. U s i n g    a    c r o s s    t i p    s c r e w d r i v e r, install   four   washers   (2)   and   screws ( 1 ). NOTE Return   M10A   Forklift   to   original equipment   condition. END OF TASK 5-216

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business