TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-43. Fuel   Level   Sending   Unit.   (Sheet   4   of   4) TESTING   (cont) 10. Connect   red   lead   on   multimeter   to terminal   and   black   lead   to   ground   on liquid    transmitter    (8). 11. Observe   needle   movement.   With   float at   FULL   position, t h e    r e s i s t a n ce range  is  240  to  260  ohms. With f l o a t    a t resistance 1 2 .    R e p l a c e    if resistance EMPTY   position,   the range   is   29   to   33.5   ohms. t e s t    i s    o u t s i d e    t h e range. INSTALLATION 13. U s i n g    a    f l a t    t i p    s c r e w d r i v e r, install   new   gasket ( 9 ) , l i q u id transmitter   (8)   and   five   screws   (7) on   right   side   of   frame i n    e n g i n e compartment. 14. Connect   wire a s s e m b l y    ( 6 )    at terminal. 1 5 .    U s i n g    a    3 / 8 ”    o p e n    e n d    w r e n c h , install   washer   (5),   lock   washer   (4) and   nut   (3).   Apply   silicone   sealant over   entire   connection. 16. I n s t a l l    i n s u l a t o r    ( 2 ) . 17. Install   engine   side   access   cover   (1) on   right   side   of   engine   compartment, refer   to   paragraph   12-4. NOTE Return   M10A   Forklift   to   original equipment   condition. END OF TASK 5-214