TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-42.   Torque   Converter   Temperature   Sender   and   Switch.   (Sheet   2   of   4) REMOVAL NOTE All    electrical    connections, except those   on   the   instrument   panel, are s e a l e d    a g a i n st moisture with s i l i c o n e sealant.    Remove a l l silicone   sealant   before   performing m a i n t e n a n c e    on e l e c t r i c a l connections. All  wire  must  be  tagged  when  removed from   connector.   Indicate   whether w i r e    i s    c o n n e c t e d    t o    p i n - t y p e    or socket-type   connector. 1. Using   a   flat   tip   screwdriver,   remove screw  (1)  from  switch  (3)  on  torque converter. 2. Disconnect   wire   assembly   (2)   at terminal. 3. Using   a   7/8”   open   end   wrench,   remove switch   (3). 4. Using   a   flat   tip   screwdriver,   remove screw   (4). 5. Disconnect   wire   assembly   (5)   at terminal. 6. Using   a   15/16”   open   end   wrench, remove   sending   unit   (6)   from   torque converter. Go  to  sheet  3 5-208