TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-41. Oil   Pressure   Switch.   (Sheet   3   of   4) CLEANING/INSPECTION Dry   cleaning solvent    P-D-680, used   for   cleaning   parts,   is   toxic and   flammable.   Use   only   in   well v e n t i l a t e d     a r e a s. Wear protective   goggles   and   gloves. Do   not   smoke   or   allow   open   flames or   sparks   in   areas   where   cleaning solvent   is   used   or   stored. Avoid contact   with eyes, s k i n    or c l o t h i n g. If   contact   with   eyes is   made,   flush   with   cold   water and seek medical attention immediately. I f    c o n t a c t    w i t h skin   or   clothing   is   made, f l u sh with   cold   water.   If   you   become dizzy w h i l e    u s i ng cleaning s o l v e n t ,    g et fresh a i r immediately. 9. 10. C l e a n    a l l    p a r t s    w i t h    c l e a n    c l o th moistened   with   cleaning solvent P-D-680. Wipe   dry   with   clean   cloth. Refer   to   paragraph   2-8. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. Go  to  sheet  4 5-205