TM   10-3930-643-20 ELECTRICAL 5 - 4 0 .    O il REMOVAL 1. 2. 3. 4. SYSTEM TROUBLESHOOTING AND MAINTENANCE. Pressure   Sending   Unit.   (Sheet   2   of   5) NOTE A l l    e l e c t r i c a l    c o n n e c t i o n s ,    e x c e pt those   on   the   instrument   panel, are s e a l e d    a g a i n st moisture with s i l i c o n e    s e a l a n t . Remove   all silicone   sealant   before   performing m a i n t e n a n c e    on e l e c t r i c al connections. All  wire  must  be  tagged  when  removed from   connector.   Indicate   whether w i r e    i s    c o n n e c t e d    t o    p i n - t y p e    or socket-type   connector. Using   a   3/8”   open   end   wrench,   remove nut   (1)   and   lock   washer   (2)   on   left side   of   engine. Disconnect   wire   assembly   (3)   at terminal. Using   a   1/2”   open  end  wrench,  remove sensor   (4). NOTE The   following   are   differences between   M10A   Forklift   models. The   removal   and   installation procedures   are   identical. S/N   2000 Remove   tee   (5)   from   vehicles   S/N 2001   and   above   or   remove   tee   (6)   and nipple   (7)   from   vehicles and   below. Go  to  sheet  3 5-199