TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-17. Voltmeter  and  Torque  Converter  Temperature  Gage.  (Sheet  1  of  2) This   task   covers: a.   Removal b . Cleaning/Inspection c.   Installation INITIAL  SETUP Tools Materials/Parts Tool   Kit,   General   Mechanic’s Detergent   (App.   C,   Item   16) Automotive Clean   cloth   (App.   C,   Item   10) NSN   5180-00-177-7033 Torques Except   for   special   torques   shown, all   fasteners   are   tightened   to   a standard   torque. Refer   to Appendix  E. EQUIPMENT  CONDITION References Condition    Description Paragraph   5-47 Battery   negative   disconnected. REMOVAL NOTE The   following   is   a   maintenance procedure   for   the   voltmeter.   The maintenance  procedure f o r    t h e torque   converter   temperature   gage i s     i d e n t i c a l. 1. U s i n g    a    c r o s s    t i p    s c r e w d r i v e rs remove   four   screws   (1)   and   bezel   (2) in   front   in   operator’s   compartment. 2. Remove   gage   (3). 3. Remove   bulb   (4)   and   socket   (5). Go  to  sheet  2 5-114

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business