TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-14. Hourmeter. (Sheet   2   of   2) REMOVAL 5. Remove   wing   nut   (8)   and   bracket   (9). 6. Remove   gage   (10). CLEANING/INSPECTION 7. W i p e    a l l    p a r t s    w i t h    c l e a n    c l o th moistened   with   mild   detergent   and water   solution.   Wipe   dry.   Refer   to paragraph   2-8. 8 . I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. INSTALLATION 9. 10. 11. 12. 13. 14. Install   gage   (10)   on   instrument panel   (3). Install   bracket   (9)   and   wing   nut ( 8 ) . Connect   wire   assemblies   (7   and   6)   at connectors. Using   a   5/16”   box   wrench,   install two   lock   washers   (5)   and   nuts   (4). Position   instrument   panel (3) in h o u s i n g     i n     f r o n t     o f     o p e r a t o r s compartment. U s i n g    a    c r o s s    t i p    s c r e w d r i v e r, install   four   washers   (2)   and   screws ( 1 ) . NOTE Return  M10A  Forklift  to  original equipment   condition. END OF TASK 5-108

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business