TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-11. Starter   Lockout   Relays.   (Sheet   5   of   5) TESTING 22. 23. 24. 25. 26. 27. 28. Test   winding   resistance   of   relay   (7) on   right   side   of   frame   in engine compartment. Connect   red   lead   on   multimeter   to terminal   (18)   and   black   lead   to terminal   (19). Observe   needle   movement.   Range   for winding   resistance   is   between 200 and  250  ohms. Replace   if   test   is   not   within   range l i m i t s . Reconnect    batteries. Apply   silicone   sealant   over   entire c o n n e c t i o n s     o f     w i r e     a s s e m b l i es (9,8,3   and   2)   on   right   side   of   frame in   engine   compartment. Install   engine   side   access   cover   (1) on   right   side   of   engine   compartment, refer   to   paragraph   12-4.   Close   latches. NOTE Return   M10A   Forklift   to   original equipment   condition. END OF TASK 5-97

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business