TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-11. Starter   Lockout   Relays.   (Sheet   4   of   5) TESTING   (cont) 15. 16. 17. 18. 19. 20. 21. Observe   needle   movement. Range  for upper   contact   opening   is   between   8 and  12  volts  dc. R e p l a c e    i f    t e s t    v o l t a g e    i s    n ot within   range   limits. Test   lower   contact   closing   voltage. Connect   red   lead   on   multimeter   to terminal   (14)   and   black l e a d    t o terminal   (16). Observe   needle   movement. Maximum f o r    l o w e r    c o n t a c t    c l o s i n g    i s    10 v o l t s    d c. Replace maximum Using   a connect if   test   voltage   is   more   than l i m i t . 1/2”   open   end   wrench, d i s - battery   negative   cable. Go  to  sheet  5 .5-96