TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-8. Instrument   Panel   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION m.  FUEL  LEVEL  GAGE  DOES  NOT  OPERATE.  (cont) Step   3. Connect   instrument   gage   tester.   Use   instructions   provided   with gage   tester.   Test   values   for   fuel   level   gage   should   read:   Run (green)   zone,   Low   empty,   High   full.   Resistance   (ohms),   Low 240,   High   34.   System   voltage,   24V. Step   4.   Test   the   continuity   of   the   wire   assembly.   Disconnect   twelve pin   connector   from   instrument   panel,   as   shown.   Disconnect instrument   panel   harness   from   intermediate   harness,   as   shown. Connect   multimeter   to   Pin   6   and   Pin   D. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. 5-60