ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. TM   10-3930-643-20 5-8. Instrument    Panel    Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION l  . TORQUE  CONVERTER  TEMPERATuRE  GAGE  WILL  NOT  OPERATE. Step   5. Test   the   continuity   of   the   wire   assembly.   Disconnect   main harness   from   intermediate   harness,   as   shown.   Connect   multi- meter  to  terminal  and  Pin  B. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e c t Support. Step  6.  Return  M10A  Forklift  to  original  equipment  condition. m. FUEL LEVEL GAGE DOES NOT OPERATE. Step   1. Remove   socket   and   check   fuel   level   gage   light   bulb. If   the   bulb   is   burned   out,   replace,   refer   to   paragraph   5-16. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   2. Remove   bezel   assembly   and   fuel   level   gage.   Test   the   continuity of   gage. Connect   multimeter   to   terminals   at   the   back   of   gage. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   fuel   level   gage,   refer   to   paragraph   5-16. 5-59