TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-8. Instrument   Panel   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION l . TORQUE  CONVERTER  TEMPERATURE  GAGE  WILL  NOT  OPERATE.  (cont) Step   3. Test   the   continuity   of   the   wire   assembly.   Disconnect   twelve pin   connector   from   instrument   panel,   as   shown.   Disconnect instrument   panel   harness   from   intermediate   harness,   as   shown. Connect   multimeter   to   Pin   1   and   Pin   B. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   4. Test   the   continuity   of   the   torque   converter   temperature   sender. Connect   multimeter   to   sending   unit   terminal   and   ground. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   torque   converter   temperature   sender,   refer   to paragraph    5-42. 5-58