TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-8. Instrument   Panel   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION c . ENGINE FAN OFF LIGHT DOES NOT OPERATE. (cont) Step   3. Test   the   continuity   of   the   wire   assembly.   Disconnect   three   pin connector   from   fan   clutch   relay,   as   shown.   Connect   multimeter to  Pin  C  and  Connector  D. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   4. Test   the   continuity   of   the   second   wire   assembly.   Disconnect Terminal   F   from   the   engine   fan   off   switch,   as   shown.   Connect multimeter   to   Terminals   E   and   F. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Identify   as   a   defective   wire   and   contact   Direct   Support Maintenance. Step   5. Return   M10A   Forklift   to   original   equipment   condition. 5-42