TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5 - 7 .    L i g h t    S y s t e m    T r o u b l e s h o o t i n g .    ( c o n t) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION d . REAR WORK LIGHT(S) DOES NOT OPERATE. (cont) NOTE Before   proceeding   with   continuity   test,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   2.   Test   the   continuity   of   the   rear   work   light   assembly.   Connect the   multimeter   to   both   terminals   at   the   back   of   the   light housing. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   rear   work   light   assembly,   refer   to   paragraph 5-36. Step  3.  Test  the  continuity  of  wire  assembly.  Disconnect  intermediate harness   from   instrument   panel   harness,   as   shown.   Connect   the multimeter   to   Terminal   A   and   to   Pin   J   at   main   harness connector. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. 5-32