TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-7.   Light   System   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION c.  FRONT  BLACKOUT  LIGHT  DOES  NOT  OPERATE.  (cont) If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    R e p l a c e    f r o n t    b l a c k o u t    l i g h t    a s s e m b l y ,    r e f e r    t o paragraph   5-34. Step   2. Test   the   continuity   of   the   wire   assembly.   Disconnect   two   pin connector   from   instrument   panel   harness,   as   shown.   Connect   the multimeter   to   Terminal   A   and   to   two   pin   connector   socket. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   3.   Test   the   continuity   of   the   light   switch.   Turn   light   switch   to BLACKOUT  position.  Disconnect  instrument  panel  harness  from switch,   as   shown.   Connect   multimeter   to   Pin   D   and   to   ground. 5-30