TM 10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-4. Starting   System   STE/ICE   Tests. c . TEST  70. STARTER SOLENOID VOLTAGE. 1. Refer   to   VTM-General   Setup   and   Checkout   Instructions   in   TM   9-4910- 571-12&P. Connect   power   cable   to   battery. 2. Disconnect   wire   lead   to   fuel   solenoid,   refer   to   paragraph   4-2, 3. 4. 5. 6. 7. A t t a c h    c a b l e    c l i p s    a s    i l l u s t r a t e d .    M a k e    s u r e    t h a t    a l l    e l e c t r i c al contacts   are   clean, refer   to   paragraph   2-13. Perform  test  using  procedure  TEST  89  as  instructed  in  TM  9-4910-571-12&P. Test   results   should   be   16   volts   minimum   and   28   volts   for   the   norm. Apply   silicone   sealant. Refer   to   paragraph   2-12.b. Return   M10A   Forklift   to   original   equipment   condition. 5-15