TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-3. Starting   System   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION b . STARTER  CRANKS  TOO  SLOWLY. NOTE Before   proceeding   with   continuity   test,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   1. Inspect   connections   of   batteries   to   insure   that   they   are   clean and   secure. If   connections   of   batteries   need   cleaning   or   securing, r e f e r    t o paragraph   2-13. Step   2. Test   battery   voltage,   refer   to   paragraph   2-13. If   battery   voltage   is   low,   refer   to   TM   9-6140-200-14. Step  3. Inspect   electrical   connections   at   starter   to   insure   that   they are   clean   and   secure. If   connections   need   cleaning   or   securing,   refer   to   paragraph   2-13. Step   4. Return   M10A   Forklift   to   original   equipment   condition. 5-12