TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-3. Starting   System   Troubleahooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE  ACTION a . STARTER MOTOR FAILS TO CRANK. (cont) Step   5. Test   the   continuity   of   the   wire   assembly.   Disconnect   Terminal   B from   neutral   start   switch,   as   shown.   With   instrument   panel harness   disconnected,   connect   multimeter   to   Pin   A   and   Terminal B. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Identify   as   a   defective   wire   and   contact   Direct   Support. Step   6. Test   the   continuity   of   the   start   switch.   Connect   multimeter   to two  terminals  at  the  back  of  switch. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   start   switch,   refer   to   paragraph   5-19. Step   7.   Test   the   continuity   of   the   wire   assembly.   Disconnect   Connector A   from   the   start   switch,   as   shown.   Disconnect   instrument   panel harness   from   intermediate   harness,   as   shown.   Connect   multimeter to   Connector   A   and   Pin   L. 5-10