ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. TM  10-3930-643-20 5-3. Starting    System    Troubleshooting. - MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION a . STARTER  MOTOR  FAILS  TO  CRANK. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for initial   setup   instructions. Step   1. Insure   that   all   controls   are   in   their   proper   position. If   forward   and   reverse   lever   is   in   forward   or   reverse   position, shift   lever   to   neutral   position. Step   2.   Inspect   electrical   connections   to   insure   that   they   are   clean and   secure. I f    e l e c t r i c a l    c o n n e c t i o n s    n e e d    c l e a n i n g    o r    s e c u r i n g ,    r e f e r    t o paragraph   2-13. Step   3. Test   the   continuity   of   the   magnetic   switch. Connect    multimeter to   terminal   and   ground. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   magnetic   switch,   refer   to   paragraph   5-32. Step   4. T e s t    c o n t i n u i t y    o f    t h e    s t a r t e r    l o c k o u t    r e l a y s . Connect multimeter   to   terminals   on   relay. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y . Replace   starter   lockout   relays,   refer   to   paragraph 5-11. 5-9