TM   10-3930-643-20 ENGINE,  FUEL,  EXHAUST  AND  COOLING  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 4-30. Radiator   Piping   and   Mounting.   (Sheet   4   of   6) CLEANING/INSPECTION 30. 31. 32. Clean   hoses   (3,   7,   10,   18,   22, 30  and  35)  with  mild  detergent water    solution. Wipe  dry  with c l o t h . •TOXIC/FLAMMABLE 26, and clean Dry   cleaning   solvent   P-D-680   used for   cleaning   parts   is   toxic   and f l a m m a b l e .    U s e    o n l y    i n    w e ll ventilated   areas.   Wear   protective goggles  and  gloves.  Do  not  smoke or   allow   open   flames   or   sparks   in areas   where   cleaning   solvent   is used   or   stored. A v o i d    c o n t a ct w i t h    e y e s ,    s k i n    o r    c l o t h i n g .    If contact   with   eyes   is   made, f l u sh with   cold   water   and   seek   medical attention   immediately.   If   contact with   skin   or   clothing   is made, flush   with   cold   water. If  y o u become   dizzy   while   using   cleaning s o l v e n t, get fresh a i r immediately. •COMPRESSED  AIR  HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h i p guarding   and   personal   protective equipment   (goggles/shield,   gloves, e t c . ) . Clean   all   other   parts   with   cleaning solvent   P-D-680. Dry   thoroughly with   compressed   air. R e f e r    t o paragraph   2-8. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. Go  to  sheet  5 4-130