TM   10-3930-643-20 ENGINE, FUEL, EXHAUST AND COOLING TROUBLESHOOTING AND MAINTENANCE. 4-20. Fuel   Filler   Cap   Assemblies.   (Sheet   3   of   4) CLEANING/INSPECTION · TOXIC/FLAMMABLE 5. 6. Dry   cleaning   solvent   P-D-680, used   for   cleaning   parts,   is   toxic and  flammable.  Use  only  in  well v e n t i l a t e d    a r e a s .    W e a r protective   goggles   and   gloves. Do   not   smoke   or   allow   open   flames or   sparks   in   areas   where   cleaning solvent   is   used   or   stored.   Avoid c o n t a c t    w i t h    e y e s ,    s k i n    o r clothing.   If   contact   with   eyes is   made,   flush   with   cold   water a n d    s e e k    m e d i c a l    a t t e n t i on i m m e d i a t e l y .    I f    c o n t a c t    w i th skin   or   clothing   is   made,   flush with  cold  water.  If  you  become d i z z y    w h i l e    u s i n g    c l e a n i ng s o l v e n t ,     g e t     f r e s h     a i r immediately. l COMPRESSED AIR HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h ip guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ) . Clean   all   parts   with   cleaning   solvent P-D-680. Dry   thoroughly   with   com- pressed   air. Refer   to   paragraph   2-8. I n s p e c t    a l l    p a r t s .    R e f e r    t o    p a r a- graph   2-9. Go  to  sheet  4 4-79