TM   10-3930-643-20 ENGINE, FUEL, EXHAUST AND COOLING TROUBLESHOOTING AND MAINTENANCE. 4-16. Air   Cleaner   Connections.   (Sheet   5   of   9) CLEANING/INSPECTION 21. Clean   hose   assembly   (5)   and   hoses (17  and  21)  with  mild  detergent  and water   solution. •  TOXIC/FLAMMABLE Dry   cleaning   solvent   P-D-680   used for   cleaning   parts,   is   toxic   and flammable. U s e    o n l y    i n    w e l l ventilated   areas.   Wear   protective goggles  and  gloves.  Do  not  smoke or   allow   open   flames   or   sparks   in areas   where   cleaning   solvent   is used   or   stored. A v o i d    c o n t a ct w i t h    e y e s ,    s k i n    o r    c l o t h i n g .    If contact   with   eyes   is   made,   flush with   cold   water   and   seek   medical attention   immediately.   If   contact with   skin   or   clothing   is made, flush   with   cold   water. I f    y ou become   dizzy   while   using   cleaning s o l v e n t ,    g et fresh a ir immediately. COMPRESSED  AIR  HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h ip guarding   and   personal   protective equipment ( g o g g l e s / s h i e l d, g l o v e s ,    e t c . ) . 22• Clean   holes   in   orificed   adapter   (2) with   .020”   mechanic’s   wire. 23. Clean   all   other   parts   with   cleaning solvent   P-D-680. Dry   thoroughly with   compressed   air. Go  to  sheet  6 4-63