TM  10-3930-638-24&P 4-3.   FUEL   SYSTEM   MAINTENANCE   (cont) b. Fuel Injection Pump (cont). STEP LOCATION ITEM ACTION REMARKS TESTING NOTE Test bench must use calibrating nozzles type DN12SD12 (open- ing pressure 2500 psi) and injection lines shall be 3/32 inch ID by 20 inches long; holder BKB50SD and 0.5 MM plate and lines 1/16 inch ID by 25 inches long; Mobil Velocite No. 3 calibrating oil  and  calibrating  oil  temperature  at  110-115  degrees  F.  Test stand coupling should be of the self-aligning zero backlash type. Mount and drive the pump according to the test bench manu- 38 39 facturer’s  instructions. Transfer  pump a. Plug (91) Remove (end  plate b. Sleeve (92) Install pump (88)) inlet connector Housing a. Four screws Remove (124) b. Two timing Remove line covers (125) NOTE Pump rotation is counterclockwise as viewed from of  pump, Connect a +24 Vdc battery and switch to solenoid top  of  governor  control  cover  (22) c. Switch connected Place in on to  battery position d. Pump throttle Move to full shaft load position assembly (37) Use two wrenches so pump outlet fitting does not move at the same time. Install transfer pressure gauge adapter P/N 21900, then a shutoff valve to isolate gauge when not in use. Connect pressure gauge to adapter P/N 21900 Install  P/N  19918  advance  windows  in NOTE 1 to 3 PSI supply pressure is required at pump inlet. place  of  timing  line  covers drive shaft end terminals  at When transfer pump is primed, bleed fuel for several seconds by loosening injection line nuts at fuel nozzles; then tighten nuts securely 4-128