TM  10-3930-638-24&P 2-56.   HYDRAULIC   LIFT   SYSTEM   MAINTENANCE   (cont) f. Hoses, Lines and Fittings (cont). (2) Mast Assembly (cont). 3 STEP LOCATION ITEM ACTION REMARKS REMOVAL  (cont) s. Tube fittings (43 and Loosen  and  dis- (cont) 44) connect t. Tube assembly (45) Remove u. Four nuts (46) Remove v. Four elbow fittings Remove (47) w. Four nuts (48) Remove x. Four fittings (49) Remove CLEANING Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don’t breathe vapors. Do not use near open flame or exces- sive heat and don’t smoke when using it. Failure to do so could cause serious injury. If you become dizzy while using cleaning solvent,  get  fresh  air  immediately,  and  get  medical  attention.  If contact with skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water immed- iately,  and  obtain  medical  aid  immediately. 4 All parts Clean Use cleaning solvent P-D-680 INSPECTION 5 Elbow fittings (3, 10,23, Inspect Replace if cracked, distorted, or threads 24, and 47), 45 degree damaged fitting (37), 90 degree fittings (38 and 39), and fitting  (49) 6 Hose  assemblies  (5,  8, Inspect Replace if cracked, split, or fitting 13,22, 33, and 36) threads   damaged 7 Tube assemblies (27, 30, Inspect Replace if cracked, kinked, dented, 42, and 45), and tension twisted,  or  fitting  threads  damaged tubes  (16) 8 Hose  springs  (15) Inspect Replace if cracked or damaged or evidence  of  permanent  set  is  obvious 2-436