4-2. ENGINE MAINTENANCE (cont)
a. Cylinder Block Assembly (cont).
REMARKS
ITEM
ACTION
LOCATION
STEP
INSPECTION (cont)
c. Measure cylin-
Check taper and out-of-roundness with
der sleeve
bore gauge. If taper or out-of-roundness
(cont)
exceeds 0.002 inch, replace block
bores
9
Cylinder sleeve (1)
a. Inspect
Replace if smooth, shiny surface along
complete length or heavy vertical lines
fringed by metal transferring from one
spot to another are observed
WARNING
Blue Vitriol solution contains acid. Wear safety glasses to protect
eyes from accidental splashing and avoid splashing solution on
skin. If solution is splashed on your skin or in your eyes, wash
off immediately with water and get medical aid.
b. Check chrome
Wet inside of sleeve with cotton swab
plating
saturated with Blue Vitriol solution. If
bright copper color is observed, replace
sleeve. Rinse tested surfaces with water
after check
NOTE
If Blue Vitriol solution cannot be obtained from druggist, a satis-
` factory solution can be made from copper sulfate crystals avail-
able at hobby stores or pharmacies. To prepare solution: add one
tablespoon fresh battery acid to one cup water; add 1/2 level
teaspoon copper sulfate crystals to solution; stir with plastic spoon
until crystals are dissolved.
c. Check sleeve
Use inside micrometer or bore gage. Check
inside diameter below top ring location and at several
for taper
points down length. Replace if taper is
more than 0.002 inch
d. Check sleeve
Use bore gage. Measure lengthwise just be-
out-of-round-
low top ring location at four points 90
ness
degrees from each other. Replace if out-
of-roundness exceeds 0.001 inch. (Use
micrometer to check bore gage.)
10
Oil falter to block
Inspect
Replace if bent or threads damaged
adapter (5) and
stud (3)
4-6

Privacy Statement - Press Release - Copyright Information. - Contact Us