NOTES:
and maintain to "FULL" mark. Change the
element each 1000 operating hours.
PROTRACTED COLD TEMPERATURES
B E L O W -15F (-26C).
Remove
9. DRIVE AXLE. Check level each 250
l u b r i c a n t s prescribed in Key for
operating hours. Change gear lubricant
t e m p e r a t u r e s above -15F (-26C).
only when required by maintenance repair
Relubricate with lubricants specified in
action, contamination by water, or other
Key for temperatures below -15F (-26C).
foreign material. After refill, operate for
If OEA lubricant is required to meet the
five minutes, check for leaks and bring oil
temperature ranges prescribed in the
level to level plug opening.
Key, OEA lubricant is to be used in place
of OE/HDO-10 lubricant for all
10. TRANSMISSION AND TORQUE CON-
temperature ranges where OE/HDO-10 is
VERTER. Check level each 10 operating
specified in the Key.
hours with oil at operating temperature.
Maintain oil level at level plug opening.
2. OIL CAN POINTS. Each 250 operating
Each 250 hours clean breather cap, lubri-
hours, lubricate clutch pedal linkage,
cate with OE/HDO oil and reinstall. To
transmission shift linkage, door latches
drain, remove transmission and torque
and hinges, pins, and clevises, and all ex-
converter drain plugs. Crank engine to
posed adjusting threads with OE/HDO.
move torque converter drain to bottom.
Drain and replace plugs. Drain when lubri-
3. ENGINE OIL LEVEL HOT OR COLD
cant is warm. Fill transmission to level
CHECK. Cold engine, oil level should be
plug opening. Operate for 5 minutes,
at high mark on dipstick. Hot engine, oil
check for leaks and bring oil level to level
level must be between high and low
plug opening.
marks on dipstick (allow to set 5 minutes
before checking).
11. HYDRAULIC SYSTEM. Check level
each 50 operating hours. Change hydrau-
4. ENGINE. Oil is to be changed each
lic oil only when required by maintenance
250 operating hours. Drain when lubricant
repair action, contamination by water, or
is warm.
other foreign material. After refill, operate
for five minutes, check for leaks and bring
5. ENGINE OIL FILTER. Each 250 operat-
oil level to level plug opening. Bleed
ing hours, remove filter element, clean
system if necessary.
housing and install new filter element.
After installing new filter element, fill
12. HYDRAULIC OIL FILTER. Each 500
crankcase, operate engine for 5 minutes,
operating hours, remove element, clean
check housing for leaks, check crankcase
filter shell and install new element. After
oil level and bring to "FULL" mark.
replacement, operate hydraulic system
for 5 minutes, check for leaks, check level
6. AIR CLEANER. Each 250 operating
and bring to "FULL" mark.
hours, disassemble entire unit, clean,
re-oil and assemble. Under extremely dus-
13. DISTRIBUTOR. Each 250 operating
ty or other unusual conditions service
hours apply GAA sparingly to breaker
each 10 operating hours.
cam. Lubricate the breaker cam pivot and
rotor wick with 2 drops of OE/HDO. Clean
7. WHEEL BEARINGS. Each 1000 oper-
vents. Add 6 drops of OE/HDO to oil cup.
ating hours, remove wheels, clean and in-
spect all parts, replace damaged or worn
14. UNIVERSAL JOINT. Each 1000
parts, repack bearings, and assemble.
operating hours, remove joint, disas-
semble, clean and inspect all parts, re-
8. POWER STEERING RESERVOIR.
place damaged or worn parts, repack
Each 50 operating hours check oil level
bearings and assemble.
TA220593